DSIP COA Elements: Testing Methods Comparison
HPLC Chromatography Purity by peak area integration ≥95% primary peak, baseline resolution Quantifies relative abundance of DSIP vs impurities Missing chromatogram image, baseline drift, split peaks, no detector wavelength listed Mass Spectrometry (ESI or MALD
This page preserves a source comparison for education. It does not add a rating, recommendation or clinical judgment.
- HPLC Chromatography
- Purity by peak area integration
- ≥95% primary peak, baseline resolution
- Quantifies relative abundance of DSIP vs impurities
- Missing chromatogram image, baseline drift, split peaks, no detector wavelength listed
- Mass Spectrometry (ESI or MALDI)
- Molecular weight confirmation
- ±1 Da from 848.81 Da expected mass
- Confirms peptide identity. Prevents substitution or degradation
- Calculated mass only (no spectrum), mass deviation >1 Da, excessive fragmentation
- Lab Accreditation (ISO 17025)
- Quality system and method validation
- ISO/IEC 17025 from recognised body
- Ensures testing procedures meet international standards
- No accreditation listed, unknown lab, self-testing by vendor
- Batch Traceability
- Links COA to specific vial
- Batch number, test date, expiration date
- Prevents COA reuse across different batches
- Batch mismatch, test date >12 months old, no expiration date
- Endotoxin Testing (LAL assay)
- Bacterial contamination levels
- <10 EU/mg for research use
- Critical for in vivo studies. Endotoxins cause immune responses
- No endotoxin data, values >50 EU/mg, or test method not stated